Mark Harris Homes

Mark Harris Homes

These are homes that have not yet completed both Roughin & Final Inspection
Search
RI = Rough-In. FN = Final.
Builder Address Request (RI) Request (FN) Requester (RI) Requester (FN) Status (RI) Status (FN) Inspected (RI) Inspected (FN)
Mar...2600 Legacy pre...09/17/2014robertPassed--09/18/2014
Submit Final
Tech Comments (RI):
Tech Comments (FN):
Mar...6323 Midtown Ln...09/19/2014robertPassed--09/22/2014
Submit Final
Tech Comments (RI):
Tech Comments (FN):
Mar...6326 Midtowne L...03/10/2015robert bas...Passed--03/11/2015
Submit Final
Tech Comments (RI):
Tech Comments (FN):
Mar...6303 Midtowne L...06/16/2015robert bas...Passed--06/23/2015
Submit Final
Tech Comments (RI):Block and seal between floor and attic in garage. block and seal duct work in garage. add air barrier on end and seal dryer vent at back wall and seal at 2 x6 and seal corner in garage. insulate block and seal across full length of joice and seal penatrations at back door. insulate and replace air barrier in attic behind shower and seal drain. please verify all work is complete before resubmitting reinspection. ------- --------insulate block and seal across full length of joice and seal penatrations at back door. insulate and replace air barrier in attic behind shower and seal drain.and completley seal penetrations between floors in garage. please verify all work is complete before resubmitting reinspection.
Tech Comments (FN):
Mar...9 Williams Way ...06/16/2015robert bas...Passed--06/19/2015
Submit Final
Tech Comments (RI):Install eve baffel and insulation barrier upstairs right side of front door. block and seal between floors supply line on garage wall. seal wires between floors on back porch. seal all duct and wires penetrations between floors in laundry room.
Tech Comments (FN):
Mar...1215 Highland A...06/22/201510/13/2015robert bas...robert bas...Not Ready--06/30/2015
Re-submit Roughin
Tech Comments (RI):Upstairs comlpete insulation under ac platform. complete seal at pvc pipe at bath and hallway. seal drains at both showers. first floor. seal drain under tub. seal all penetrations between floors and attic. stuffed insulation in not a seal. basement. complete insulation at band on east side behind duct work in bedroom and shower area and back corner. seal concrete block seam at top of stairs. insulate abd block and seal both sides of stairs between floors and crawlspace. insulate and block and seal back wall between floor and crawlspace and seal all penetrations. foam board back wall under stairs. please verify all work is complete before requesting reinspection.------- --------seal all penetrations between floors and attic. stuffed insulation in not a seal. basement. complete insulation at band on east side behind duct work in bedroom and shower area and back corner. block and seal both sides of stairs between floors and crawlspace and seal all penetrations. ple ase verify all work is complete before requesting reinspection.
Tech Comments (FN):
Mar...1213 Highland A...06/22/201510/13/2015robert bas...robert bas...Not Ready--06/30/2015
Re-submit Roughin
Tech Comments (RI):Basement complete seal on duct work under stairs and insulate concrete wall under stairs.seal all blocking and penetrations between floors.first floor complete air barrier bottom of attic wall bottom of stairs.top floor properly insulate and complete air barrier at top of door. complete seal on all duct work. seal hole on attic wall at bottom in attic.seal top plate behind shower.please verify all work is complete before resubmitting request for reinspect.------- --------top floor. complete seal on all ductwork in attic leading between floors. and properly install insulation over attic door. and seal top plate of shower. reinstall insulation above stairs and in stairwell ceiling. basement. seal all edges of blocking leading to crawlspace and seal all penetrations leading into crawlspace. resubmit when work is complete and house is ready.
Tech Comments (FN):
Mar...102 Stone river...08/17/201512/01/2015robert bas...robert bas...Not Ready--08/21/2015
Re-submit Roughin
Tech Comments (RI):Upstairs. add insulation barrier to all attic walls. downstairs. seal hole in air barriet at cantilevered floor on right side. block and seal between floors on garage walls. seal holes and penetrations in attic walls at laundry room. garage. insulation in garage ceiling must be in continous contact with sub floor above and secured in place. complete insulation on garage band. complete garage ceiling insulation to open end of garage. block and seal garage ceiling insulation 3 joist over from lvlplease verify all work is complete and verified complete before requesting recheck. ------- --------seal penetration over front porch between floors. add air barrier on attic wall in closet upstairs.
Tech Comments (FN):
Mar...2602 Pansy St 3...10/05/2017joelPassed--10/10/2017
Submit Final
Tech Comments (RI):Downstairs-insulate area above front door where insulation can't be blown. -seal gap around water heater and fill double 2x4 wall with insulation.
Tech Comments (FN):
Mar...2054 Edinburgh ...11/13/2017joelPassed--11/14/2017
Submit Final
Tech Comments (RI):
Tech Comments (FN):
Mar...1409A Wells Ave...11/22/2017robert bas...Passed--11/22/2017
Submit Final
Tech Comments (RI):
Tech Comments (FN):
Mar...189 Somerton Dr...11/29/2017mark harri...Passed--11/30/2017
Submit Final
Tech Comments (RI):
Tech Comments (FN):
Mar...1409B Wells Ave...12/11/2017robertPassed--12/12/2017
Submit Final
Tech Comments (RI):
Tech Comments (FN):
Mar...2322 Brandon St...12/14/2017mark harri...Passed--12/26/2017
Submit Final
Tech Comments (RI):Upstairs- install solid top plate on one attic chase. install air barrier behind duct chase on opposite wall. rafter or subfloor can't be used as return plenum on both returns.
Tech Comments (FN):
Mar...1302 Highland A...12/18/2017joelPassed--12/19/2017
Submit Final
Tech Comments (RI):
Tech Comments (FN):
Mar...238 Somer bridg...12/19/2017mark harri...Passed--12/20/2017
Submit Final
Tech Comments (RI):
Tech Comments (FN):
Mar...191 Somerton Dr...12/21/2017robertPassed--12/22/2017
Submit Final
Tech Comments (RI):Add air barrier on both sides of wall behind fireplace where hole was cut.
Tech Comments (FN):
Mar...123 Stone river...01/15/2018mark harri...Passed--01/17/2018
Submit Final
Tech Comments (RI):
Tech Comments (FN):

© Copyright Huntsville Utilities Forms Support FAQ Supported Browsers Privacy Policy Terms of Use Site Map
Huntsville Utilities is an equal opportunity residential utility service provider. We do not discriminate in the terms, conditions, or provision of services based on race, color, religion, sex, disability, familial status, or national origin.

Huntsville Utilities es un proveedor de servicios residenciales publicos (electricidad, gas y agua) que ofrece igualdad de oportunidades. Nosotros no discriminamos en los terminos, las condiciones, o las provisiones de nuestros servicios basados en la raza, religion, color, sexo, discapacidad, estado familiar u origen nacional.